Notes: Values shown are from the example within the complete I&M manual.
Changes made in the Setting Mode are saved by returning to Measurement
Mode before powering off the unit.
Comparator Setting Mode
Loop Check Mode
Measurement Mode
Press less
t
han 3 sec.
(In Case of Intact)
(In Case of Intact)
(In Case of Analog Output)
Press 3 sec.
or longer
MODE
MODE
Comparator 1 Use/No Use
MODE
After 1 second
US1
USE
USE
noU
Select with
X W
keys
Message displayed
Current setting
In use Not in use
Setting Storage of Comparator
MODE
After 1 second
Sav
5-I
5-I
5-2
Message displayed
Storage Area Indication
Storage Area 1 Storage Area 2
Comparator 1 Setting Point A
MODE
After 1 second
A-1
5.00
Message displayed
Current setting
X
W
set any desired value within the
–1999 to 9999 range with UP/Down keys
MODE
Comparator 1 ON Delay
After 1 second
on1
0.00
Message displayed
Current setting
X W
set any desired value within the
0 to 2 sec range with UP/Down keys
Comparator 1 Setting Point B
After 1 second
b-1
1.00
Message displayed
Current setting
X W
set any desired value within the
–1999 to 9999 range with UP/Down keys
MODE
MODE
Comparator 1 OFF Delay
After 1 second
oF1
0.00
Message displayed
Current setting
X W
set any desired value within the
0 to 2 sec range with UP/Down keys
Select
X W
keys/reading by long pushing
Select
X W
keys/reading by long pushing
Comparator 2 Use/No Use
M
ODE
After 1 second
US2
USE
USE
noU
Select with
X W
keys
Message displayed
Current setting
In use Not in use
Comparator 2 Setting Point A
MODE
After 1 second
A-2
5.00
Message displayed
Current setting
X W
set any desired value within the
–1999 to 9999 range with UP/Down keys
MODE
Comparator 2 ON Delay
After 1 second
on2
0.00
Message displayed
Current setting
X W
set any desired value within the
0 to 2 sec range with UP/Down keys
Comparator 2 Setting Point B
After 1 second
b-2
1.00
Message displayed
Current setting
X W
set any desired value within the
–1999 to 9999 range with UP/Down keys
MODE
MODE
Comparator 1 OFF Delay
After 1 second
on2
0.00
Message displayed
Current setting
X W
set any desired value within the
0 to 2 sec range with UP/Down keys
MODE
Loop Check Mode
After 1 second
Lop
7.52
Message displayed
Before mode shift
setting value
X W
key to select an arbitrary number
between -10 to 110%F.S. of the current
dispaly unit for simulating the pressure
Setting Loading of Comparator
MODE
After 1 second
Lod
L-1
L-1
l-2
Message displayed
Storage Area Indication
Storage Area 1 Storage Area 2
Function Setting Mode Menu